UMDNI3015 UM
|
This is a 15W medical device inlet AC/DC Power Adapter. It is a AC/DC Power Adapter with a compact case size. This model is ideal as a power supply for medical devices and supports 2MOPP means of patient protection and 2xMOOP means of operator protection. IEC60601-1 and PSE certified. ProductsSeries Name:UMDNI3015 UM |
|
ProductsDetails
| Size | L:75.0 W:50.6 H:29.8/mm(IEC 320 C8) |
|---|---|
| AC Input Rating (AC Input Rating) | 90V~264V |
| DC Output Rating (DC Output Rating) |
|
| Safety |
|
| Use Case Examples | Introduction of Products by Application (PDF) |
If you are looking for Products other than the above specifications, please contact our sales team.
Contact Form
The UMDN 15W Series is a desktop AC/DC adapter (15W class) for medical equipment. It complies with the medical safety standard 60601-1 and supports 2xMOPP (Means of Patient Protection). Two types, UMDNI3015 and UMDNB3015, are available to meet medical power supply design requirements.
Compliant with Energy Efficiency Level VI (ErP/DoE), it comes standard with protection circuits for short circuit, overvoltage, and overcurrent (overtemperature protection available as an option). As an LPS (Limited Power Source) compliant medical desktop adapter, it is widely suitable for medical equipment power applications.
| UNIFIVE Reasons to Choose Us: As a power supply manufacturer with over 35 years of development experience, we provide comprehensive support from specification review for mass production, certification acquisition, production launch, to post-mass production follow-up. Based on standard products, we offer flexible supply according to volume requirements, from small-lot prototyping and evaluation to small- and medium-scale production, as well as large-volume production. We also support semi-custom solutions and assist with power supply selection from the specification planning stage toward mass production adoption. |
Key Features
1) Compliant with Medical Standard 60601-1 and Supports 2xMOPP
Compliant with the medical safety standard 60601-1 and supports 2xMOPP (Means of Patient Protection) as a patient protection measure. Ensures a high level of safety as a built-in power supply for medical equipment.
2) Two Desktop Types
Available in two types: UMDNI3015 and UMDNB3015. The desktop design enables stable power supply for stationary medical equipment.
3) Protection Circuits (Overtemperature Protection Optional)
Equipped as standard with short circuit, overvoltage, and overcurrent protection. In addition, overtemperature protection (Over Temperature Protection) can be added as an option.
4) Energy Efficiency (ErP/DoE Level VI)
Energy Efficiency Level VI (ErP/DoE) compliant. Meets the requirements of EU ErP Regulation (Commission Regulation (EU) 2019/1782) and DOE (10 CFR Part 429 and 430), with no-load power consumption of 0.1W.
5) EMC (Emissions)
Compliant with FCC Part18-B, EN(CISPR)55011-B, VCCI-B, and BS EN55011.
6) Immunity
In accordance with EN60601-1-2 and BS EN60601-1-2 requirements, compliant with EN61000-4-2/-3/-4/-5/-6/-8/-11 immunity standards.
Ideal Applications
- Selecting a desktop-type external power supply compliant with medical standard 60601-1
- Designing medical equipment based on a 2xMOPP compliant power supply
- Designing power systems for stationary medical equipment using a 15W-class desktop adapter
- Organizing protection requirements including overtemperature protection (optional) for power design
- Designing equipment based on an LPS (Limited Power Source) compliant power supply
Applications
Widely applicable as an external power supply for medical equipment.
- Stationary medical equipment
- Medical devices for clinics and medical offices
- Patient monitoring equipment
- Compact medical devices, etc.
*The above are examples and do not limit the applications.
Standards and Compliance
| Item | Details |
|---|---|
| Technical Standards | 60601-1 (medical standard), 2xMOPP compliant |
| Efficiency | Energy Efficiency Level VI (ErP/DoE), compliant with EU 2019/1782 and DOE 10 CFR Part 429 and 430 |
| EMC (Emissions) | FCC Part18-B / EN(CISPR)55011-B / VCCI-B / BS EN55011 |
| Immunity | EN60601-1-2 / BS EN60601-1-2, EN61000-4-2/-3/-4/-5/-6/-8/-11 |
| Protection Circuits | Short circuit / Overvoltage / Overcurrent protection, Overtemperature protection (Optional) |
| Operating Environment | Input: AC100-240V (range: AC90-264V), 50/60Hz (range: 47-63Hz) / Operating temperature: 0-40C (natural air cooling, above sea level) / Storage temperature: -20-65C (natural air cooling, above sea level) / Operating and storage humidity: 5-95%RH (no condensation) |
| Reference: Representative Models | 5.0V 2.5A / 5.9V 2.3A / 5.9V 2.5A / 9.0V 1.6A / 12.0V 1.2A / 15.0V 1.0A / 18.0V 0.8A / 18.0V 0.83A / 24.0V 0.65A (±5%, no-load power consumption 0.1W) |
| Reference: Types | UMDNI3015 / UMDNB3015 (desktop type, 2 types) |
| Reference: Dimensions | 75.0x50.6x29.8mm |
| Other | LPS compliant, RoHS 2 compliant |
Semi-Custom Support
Please feel free to contact us for specification confirmation, quotations, or sample requests. You can review our semi-custom support cases on the Customization Case Studies page.