UMVUA3015 UMVU
|
This is a 15W AC adapter for medical equipment. It supports 2MOPP patient protection and 2xMOOP operator protection. The AC plug is an Australia-certified type. Featuring a small case size, this compact AC/DC Power Adapter is an ideal power supply model for medical devices and is a high-efficiency product that complies with the U.S. efficiency standard, DOE Level VI. ProductsSeries Name:UMVUA3015 UMVU |
|
ProductsDetails
| Size | L:70.0 W:38.0 H:57.0/mm |
|---|---|
| AC Input Rating (AC Input Rating) | 90V~264V |
| DC Output Rating (DC Output Rating) |
|
| Safety |
|
| Use Case Examples | Introduction of Products by Application (PDF) |
If you are looking for Products other than the above specifications, please contact our sales team.
Contact Form
The UMVU 15W Series is a wall-mount AC/DC adapter (15W class) for medical equipment. It complies with the medical safety standard 60601-1 and supports 2xMOPP / 2xMOOP. The lineup includes nine types: UMVUU3015 / UMVUZ3015 / UMVUE3015 / UMVUK3015 / UMVUA3015 / UMVUR3015 / UMVUF3015 / UMVUG3015 / UMVUL3015. With plug configurations tailored to the power standards of various countries and regions, it supports the global deployment of medical devices.
Compliant with Energy Efficiency Level VI (ErP / DoE), it is equipped as standard with protection circuits for short circuit, overvoltage, and overcurrent. As a compact medical adapter supporting LPS (Limited Power Source), it is widely applicable as a power supply for medical equipment and healthcare devices.
| UNIFIVE is chosen because: As a power supply manufacturer with over 35 years of development experience, we provide comprehensive support from specification review with mass production in mind to certification acquisition, production launch, and post-mass-production follow-up. Based on standard products, we offer flexible supply according to production volume, from small-lot prototyping and evaluation to small- and medium-scale production, and up to large-scale mass production. We also support semi-custom solutions and assist in power supply selection from the specification planning stage toward mass production adoption. |
Key Features
1) Compliant with Medical Standard 60601-1 and Supports 2xMOPP / 2xMOOP
Compliant with the medical safety standards 60601-1 and CNS14336, and supports 2xMOPP (Means of Patient Protection) and 2xMOOP (Means of Operator Protection) as patient protection measures. It also complies with IEC / EN 60601-1-2, achieving a highly safe design as a built-in power supply for medical equipment.
2) Extensive Lineup: 9 Wall-Mount Types and 10 Models
Available in 9 types: UMVUU3015 / UMVUZ3015 / UMVUE3015 / UMVUK3015 / UMVUA3015 / UMVUR3015 / UMVUF3015 / UMVUG3015 / UMVUL3015. The output voltage lineup includes 10 models ranging from 3.3V to 24.0V, meeting a wide range of voltage requirements for medical equipment.
3) Protection Circuits
Equipped as standard with short circuit protection / overvoltage protection / overcurrent protection.
4) Energy Efficiency (ErP / DoE Level VI)
Energy Efficiency Level VI (ErP / DoE) compliant. Meets the requirements of EU ErP Regulation (COMMISSION REGULATION (EU) 2019/1782) and DOE (10 CFR Part 429 and 430).
5) EMC (Emissions)
Compliant with FCC Part18 Class B, VCCI Class B, CE CISPR11 (EN55011), CNS13438, and BS EN55011.
6) Immunity
Compliant with medical EMC immunity requirements of EN60601-1-2 / BS EN60601-1-2.
Effective Use Cases
- Selecting an external power supply compliant with medical standard 60601-1
- Designing medical equipment based on a power supply that supports 2xMOPP / 2xMOOP
- Choosing the optimal power supply from a rich lineup of 9 types and 10 models in the 15W class
- Selecting a medical power supply that meets ErP / DoE Level VI energy efficiency requirements
- Designing equipment based on a power supply that supports LPS (Limited Power Source)
Applications
Widely applicable as an external power supply for medical equipment and healthcare devices.
- Home healthcare equipment
- Healthcare devices and health management equipment
- Patient monitoring equipment
- Compact medical devices, etc.
*The above are examples and do not limit the applications.
Standards and Compliance
| Item | Details |
|---|---|
| Technical Standards | 60601-1 (medical standard) / CNS14336, supports 2xMOPP / 2xMOOP |
| Efficiency | Energy Efficiency Level VI (ErP / DoE), compliant with EU 2019/1782, DOE 10 CFR Part 429 and 430 |
| EMC (Emissions) | FCC Part18 Class B / VCCI Class B / CE CISPR11 EN55011 / CNS13438 / BS EN55011 |
| Immunity | EN60601-1-2 / BS EN60601-1-2 |
| Protection Circuits | Short circuit protection / overvoltage protection / overcurrent protection |
| Operating Environment | Input: AC100-240V (range: AC90-264V), 50/60Hz (range: 47-63Hz) / Operating temperature: 0-40°C (natural air cooling, at sea level) / Storage temperature: -20-65°C (natural air cooling, at sea level) / Operating & storage humidity: 5-95%RH (no condensation) |
| Reference: Representative Models | 3.3V 2.5A / 5.0V 2.5A / 5.5V 2.5A / 5.9V 2.3A / 7.5V 2.0A / 9.0V 1.6A / 12.0V 1.25A / 15.0V 1.0A / 18.0V 0.8A / 24.0V 0.65A (Output accuracy ±5% (3.3V model: -5% to +8%)) |
| Reference: Plug Types | UMVUU3015 / UMVUZ3015 / UMVUE3015 / UMVUK3015 / UMVUA3015 / UMVUR3015 / UMVUF3015 / UMVUG3015 / UMVUL3015 (wall-mount, 9 fixed plug types) |
| Reference: Dimensions | 70.00 x 35.00 x 48.00-66.30mm (varies by plug type) |
| Other | LPS compliant, RoHS 2 compliant |
Semi-Custom Support