UMVUZ3015 UMVU
|
This is a high-efficiency 15W medical AC/DC Power Adapter that complies with the U.S. efficiency standard DOE Level VI. It supports 2MOPP means of patient protection and 2xMOOP means of operator protection. The AC pin is a China certification type. Featuring a small case size, this compact AC/DC Power Adapter is an ideal power supply model for medical equipment. ProductsSeries Name:UMVUZ3015 UMVU |
|
ProductsDetails
| Size | 70.0*35.0*48.0 |
|---|---|
| AC Input Rating (AC Input Rating) | 90V~264V |
| DC Output Rating (DC Output Rating) |
|
| Safety |
|
| Use Case Examples | Introduction of Products by Application (PDF) |
If you are looking for Products other than the above specifications, please contact our sales team.
Contact Form
The UMVU 15W Series is a wall-mount AC/DC adapter (15W class) for medical equipment. It complies with the medical safety standard 60601-1 and supports 2xMOPP / 2xMOOP. The lineup includes nine types: UMVUU3015 / UMVUZ3015 / UMVUE3015 / UMVUK3015 / UMVUA3015 / UMVUR3015 / UMVUF3015 / UMVUG3015 / UMVUL3015, enabling global deployment of medical devices with plug configurations tailored to the power standards of each country and region.
Compliant with Energy Efficiency Level VI (ErP / DoE), it comes standard with protection circuits for short circuit, overvoltage, and overcurrent. As a compact medical adapter supporting LPS (Limited Power Source), it is widely suitable as a power supply for medical equipment and healthcare devices.
| UNIFIVE Reasons to Choose Us: As a power supply manufacturer with over 35 years of development experience, we provide comprehensive support from specification review for mass production adoption to certification acquisition, mass production launch, and post-production follow-up. Based on standard products, we offer flexible supply tailored to volume requirements, from small-lot prototyping and evaluation to small and medium-scale production, and up to large-volume manufacturing. We also support semi-custom solutions and assist with power supply selection from the specification review stage for mass production adoption. |
Key Features
1) Compliant with Medical Standard 60601-1 and Supports 2xMOPP / 2xMOOP
Compliant with the medical safety standard 60601-1 and CNS14336, and supports 2xMOPP (Means of Patient Protection) and 2xMOOP (Means of Operator Protection) as patient protection measures. It also complies with IEC / EN 60601-1-2, ensuring a highly safe design as an embedded power supply for medical equipment.
2) Extensive Lineup of 9 Wall-Mount Types and 10 Models
Available in 9 types: UMVUU3015 / UMVUZ3015 / UMVUE3015 / UMVUK3015 / UMVUA3015 / UMVUR3015 / UMVUF3015 / UMVUG3015 / UMVUL3015. Output voltages range from 3.3V to 24.0V across 10 models, meeting the voltage requirements of a wide variety of medical devices.
3) Protection Circuits
Equipped as standard with short-circuit protection / overvoltage protection / overcurrent protection.
4) Energy Efficiency (ErP / DoE Level VI)
Energy Efficiency Level VI (ErP / DoE) compliant. Meets the requirements of EU ErP Regulation (COMMISSION REGULATION (EU) 2019/1782) and DOE (10 CFR Part 429 and 430).
5) EMC (Emission)
Complies with FCC Part18 Class B, VCCI Class B, CE CISPR11 (EN55011), CNS13438, and BS EN55011.
6) Immunity
Complies with medical EMC immunity requirements of EN60601-1-2 / BS EN60601-1-2.
Effective Use Cases
- When selecting an external power supply compliant with medical standard 60601-1
- When designing medical equipment based on a power supply supporting 2xMOPP / 2xMOOP
- When selecting the optimal power supply from a wide lineup of 9 types and 10 models in the 15W class
- When selecting a medical power supply that meets ErP / DoE Level VI energy efficiency requirements
- When designing equipment based on a power supply supporting LPS (Limited Power Source)
Applications
Widely applicable as an external power supply for medical equipment and healthcare devices.
- Home healthcare equipment
- Healthcare and wellness devices
- Patient monitoring equipment
- Compact medical devices, etc.
*The above are examples and do not limit the applications.
Standards and Compliance
| Item | Details |
|---|---|
| Technical Standards | 60601-1 (medical standard) / CNS14336, supports 2xMOPP / 2xMOOP |
| Efficiency | Energy Efficiency Level VI (ErP / DoE), compliant with EU 2019/1782 and DOE 10 CFR Part 429 and 430 |
| EMC (Emission) | FCC Part18 Class B / VCCI Class B / CE CISPR11 EN55011 / CNS13438 / BS EN55011 |
| Immunity | EN60601-1-2 / BS EN60601-1-2 |
| Protection Circuits | Short-circuit protection / overvoltage protection / overcurrent protection |
| Operating Environment | Input: AC100-240V (range: AC90-264V), 50/60Hz (range: 47-63Hz) / Operating temperature: 0-40°C (natural convection, altitude) / Storage temperature: -20-65°C (natural convection, altitude) / Operating & storage humidity: 5-95%RH (no condensation) |
| Reference: Representative Models | 3.3V 2.5A / 5.0V 2.5A / 5.5V 2.5A / 5.9V 2.3A / 7.5V 2.0A / 9.0V 1.6A / 12.0V 1.25A / 15.0V 1.0A / 18.0V 0.8A / 24.0V 0.65A (Output accuracy ±5% (3.3V model: -5% to +8%)) |
| Reference: Plug Types | UMVUU3015 / UMVUZ3015 / UMVUE3015 / UMVUK3015 / UMVUA3015 / UMVUR3015 / UMVUF3015 / UMVUG3015 / UMVUL3015 (wall-mount, 9 fixed plug types) |
| Reference: Dimensions | 70.00 x 35.00 x 48.00-66.30mm (varies by plug type) |
| Other | LPS compliant, RoHS 2 compliant |
Semi-Custom Support
Please feel free to contact us for specification confirmation, quotations, or sample requests. You can view examples of our semi-custom support on the Customization Case Studies page.