UMVUG3018 UMVU
|
This is an 18W AC/DC Power Adapter for medical devices. The AC pins are V-shaped Type O. It supports 2xMOPP patient protection and 2xMOOP operator protection. Its small enclosure makes it a compact AC/DC Power Adapter. This model is ideal as a power supply for medical devices. This highly efficient product also meets the U.S. DOE Level VI efficiency standard. Products Series Name:UMVUG3018 UMVU |
|
Products Details
| Size | L:70.0 W:38.0 H:57.0/mm |
|---|---|
| AC Input Rating | 90V~264V |
| DC Output Rating |
|
| Safety |
|
| Application Examples by Use Case | Introduction to Products by Application (PDF) |
If you are looking for a Products with specifications other than those listed above, please contact our sales team.
Contact Form
The UMVU 18W Series consists of wall-mount AC/DC adapters for medical devices (18W class). They comply with the 60601-1 medical device safety standard and support 2xMOPP/2xMOOP. The lineup includes nine types: UMVUU3018/UMVUZ3018/UMVUE3018/UMVUK3018/UMVUA3018/UMVUR3018/UMVUF3018/UMVUG3018/UMVUL3018. Plug configurations compatible with the power standards of various countries and regions support the global deployment of medical devices.
Compliant with Energy Efficiency Level VI (ErP/DoE), these adapters come standard with short-circuit, overvoltage, and overcurrent protection circuits. This compact medical adapter complies with LPS (Limited Power Source) requirements and is suitable for powering a wide range of medical equipment and healthcare devices.
| Why Choose UNIFIVE: As a power supply manufacturer with more than 35 years of development experience, we provide consistent support covering specification review, certification, mass-production launch, and post-production follow-up, with mass-production adoption in mind. Based on our standard products, we offer flexible supply to meet a range of volume requirements, from small-lot prototyping and evaluation to small- and medium-scale production and high-volume production. We also offer semi-custom solutions and support power supply selection from the specification review stage through mass-production adoption. |
Key Features
1) Compliant with Medical Device Standard 60601-1 and Supports 2xMOPP/2xMOOP
Compliant with the 60601-1 and CNS14336 medical device safety standards, these adapters support 2xMOPP (Means of Patient Protection) and 2xMOOP (Means of Operator Protection). They also support IEC/EN 60601-1-2, providing a highly safe design for use as power supplies in medical devices.
2) Extensive Lineup of 9 Wall-Mount Types and 10 Models
The lineup includes nine types: UMVUU3018/UMVUZ3018/UMVUE3018/UMVUK3018/UMVUA3018/UMVUR3018/UMVUF3018/UMVUG3018/UMVUL3018. Ten models are available with output voltages ranging from 3.3V to 24.0V, meeting the voltage requirements of a wide range of medical devices.
3) Protection Circuits
Standard protection circuits include short-circuit protection, overvoltage protection, and overcurrent protection.
4) Energy Efficiency (ErP/DoE Level VI)
Compliant with Energy Efficiency Level VI (ErP/DoE). These adapters meet the requirements of the EU ErP regulation (COMMISSION REGULATION (EU) 2019/1782) and DOE regulations (10 CFR Parts 429 and 430).
5) EMC (Emissions)
Supports FCC Part 18 Class B, VCCI Class B, CE CISPR11 (EN55011), CNS13438, and BS EN55011.
6) Immunity
Meets the medical EMC immunity requirements of EN60601-1-2/BS EN60601-1-2.
Recommended Use Cases
- When selecting an external power supply compliant with the 60601-1 medical device standard
- When designing medical devices based on the use of a power supply supporting 2xMOPP/2xMOOP
- When selecting the optimal 18W-class power supply from an extensive lineup of nine types and ten models
- When selecting a medical power supply that meets ErP/DoE Level VI energy-efficiency requirements
- When designing equipment based on the use of an LPS (Limited Power Source)-compliant power supply
Applications and Usage Examples
Widely applicable as external power supplies for medical equipment and healthcare devices.
- Home healthcare equipment
- Healthcare devices and health management equipment
- Patient monitoring equipment
- Compact medical equipment, etc.
*The examples above are illustrative and do not limit the applications.
Standards and Compliance
| Item | Details |
|---|---|
| Technical Standards | 60601-1 (medical device standard)/CNS14336, supports 2xMOPP/2xMOOP |
| Efficiency | Energy Efficiency Level VI (ErP/DoE), compliant with EU 2019/1782 and DOE 10 CFR Parts 429 and 430 |
| EMC (Emissions) | FCC Part 18 Class B/VCCI Class B/CE CISPR11 EN55011/CNS13438/BS EN55011 |
| Immunity | EN60601-1-2/BS EN60601-1-2 |
| Protection Circuits | Short-circuit protection/overvoltage protection/overcurrent protection |
| Operating Environment | Input: AC100-240V (allowable range: AC90-264V), 50/60Hz (allowable range: 47-63Hz)/Operating temperature: 0-40°C (natural convection, at sea level)/Storage temperature: -20-65°C (natural convection, at sea level)/Operating and storage humidity: 5-95%RH (non-condensing) |
| Reference: Representative Model | 3.3V 3.0A/5.0V 3.0A/5.5V 3.0A/5.9V 2.8A/7.5V 2.4A/9.0V 2.0A/12.0V 1.5A/15.0V 1.2A/18.0V 1.0A/24.0V 0.75A (output accuracy: +/-5%; -5% to +8% for the 3.3V model) |
| Reference: Plug Types | UMVUU3018/UMVUZ3018/UMVUE3018/UMVUK3018/UMVUA3018/UMVUR3018/UMVUF3018/UMVUG3018/UMVUL3018 (nine wall-mount fixed-plug types) |
| Reference: Dimensions | 70.00 x 35.00 x 48.00-66.30mm (varies by plug type) |
| Other | LPS support, RoHS 2 compliant |
Semi-Custom Solutions
Please feel free to contact us regarding specification confirmation, quotations, or samples. Examples of semi-custom solutions are available on our Customization Examples page.