UMXRX3018 4-direction AC pin interchangeable type
|
The UMXRX3018 is an 18W interchangeable AC plug AC/DC Power Adapter compliant with the latest medical standard 60601-1. It supports 2xMOPP, ensuring safety in medical environments. The detachable AC plug allows compatibility with power outlets in various countries, enabling seamless use worldwide. Its four-directional connection design keeps wiring environments in medical settings neat and organized, achieving efficient space utilization. ProductsSeries Name:UMXRX3018 4-direction AC pin interchangeable type |
Option |
ProductsDetails
| Size | L:78.0 W:42.0 H:61.0/mm |
|---|---|
| AC Input Rating (AC Input Rating) | 90V~264V |
| DC Output Rating (DC Output Rating) |
|
| Safety |
|
| Use Case Examples | Introduction of Products by Application (PDF) |
If you are looking for Products other than the above specifications, please contact our sales team.
Contact Form
The UMXRX 18W Series is an AC/DC adapter for medical devices (18W class) with interchangeable AC pins. Six types of interchangeable AC pins (UMXRL/UMXRZ/UMXRE/UMXRR/UMXRK/UMXRA) are available, allowing a single adapter unit to support outlet standards in multiple countries and regions. The AC pins can be mounted in four directions, preventing interference with adjacent outlets.
Compliant with the medical safety standard 60601-1 and supporting 2xMOPP (Means of Patient Protection). This medical adapter also meets Energy Efficiency Level VI (ErP/DoE) and supports operation at altitudes up to 5,000m.
| UNIFIVE Reasons to Choose Us: As a power supply manufacturer with over 35 years of experience in power development, we provide comprehensive support from specification review for mass production adoption to certification acquisition, mass production launch, and post-production follow-up. Based on standard products, we offer flexible supply according to production volume, from small-lot prototyping and evaluation to small- and medium-scale production and large-volume manufacturing. We also support semi-custom solutions and assist with power supply selection from the specification planning stage toward mass production adoption. |
Key Features
1) Interchangeable AC pins with four-direction mounting
Six types of interchangeable AC pins (UMXRL/UMXRZ/UMXRE/UMXRR/UMXRK/UMXRA) are available, enabling a single adapter unit to support outlet standards in multiple countries and regions. Designed for four-direction mounting, the AC pins do not obstruct adjacent outlets. Excellent portability makes it ideal for highly mobile medical devices.
2) Compliant with medical standard 60601-1 and supports 2xMOPP
Compliant with the medical safety standard 60601-1 and supporting 2xMOPP (Means of Patient Protection) as a patient protection measure. Provides a high level of safety as an embedded power supply for medical devices.
3) Protection circuits (optional over-temperature protection)
Equipped as standard with short-circuit protection/overvoltage protection/overcurrent protection. In addition, over-temperature protection (Over Temperature Protection) is available as an option.
4) Supports operation at altitudes up to 5,000m
Supports operation at altitudes up to 5,000m, making it suitable for medical equipment used in high-altitude environments.
5) Energy efficiency (ErP/DoE Level VI)
Energy Efficiency Level VI (ErP/DoE) compliant. Meets the requirements of EU ErP Regulation (Commission Regulation (EU) 2019/1782) and DOE (10 CFR Part 429 and 430), with no-load power consumption of 0.1W.
6) EMC (Emissions)
Compliant with FCC Part18-B, EN(CISPR)55011-B, VCCI-B, and BS EN55011.
7) Immunity
Based on the requirements of EN60601-1-2/BS EN60601-1-2, compliant with immunity standards EN61000-4-2/-3/-4/-5/-6/-8/-11.
Effective Use Cases
- When you want a single adapter to support outlet standards in multiple countries and regions (global deployment/portable use)
- When selecting an interchangeable plug adapter compliant with medical standard 60601-1 and supporting 2xMOPP
- When seeking a design that allows four-direction mounting without obstructing adjacent outlets
- When selecting a power supply suitable for medical devices used at high altitudes (up to 5,000m operating altitude)
- When designing equipment based on a power supply compliant with LPS (Limited Power Source)
Applications
Widely applicable as an external power supply for medical devices requiring global deployment and mobility.
- Portable medical devices used during overseas business trips or travel
- Global medical devices deployed in multiple countries
- Medical devices used in high-altitude environments
- Home healthcare equipment and healthcare devices, etc.
*The above are examples and do not limit the applications.
Standards and Compliance
| Item | Details |
|---|---|
| Technical standards | 60601-1 (medical standard), 2xMOPP compliant |
| Efficiency | Energy Efficiency Level VI (ErP/DoE), compliant with EU 2019/1782, DOE 10 CFR Part 429 and 430 |
| EMC (Emissions) | FCC Part18-B/EN(CISPR)55011-B/VCCI-B/BS EN55011 |
| Immunity | EN60601-1-2/BS EN60601-1-2, EN61000-4-2/-3/-4/-5/-6/-8/-11 |
| Protection circuits | Short-circuit protection/overvoltage protection/overcurrent protection, over-temperature protection (Optional) |
| Operating environment | Input: AC100-240V (range: AC90-264V), 50/60Hz (range: 47-63Hz)/Operating temperature: 0-40°C (natural air cooling, above sea level)/Storage temperature: -20-65°C (natural air cooling, above sea level)/Operating & storage humidity: 5-95%RH (no condensation)/Operating altitude: up to 5,000m |
| Reference: Representative models | 5.0V 3.0A/5.9V 3.0A/12.0V 1.5A/15.0V 1.2A/24.0V 0.75A (output accuracy ±5%, no-load power consumption 0.1W) |
| Reference: AC pins | UMXRL/UMXRZ/UMXRE/UMXRR/UMXRK/UMXRA (6 interchangeable AC pin types, four-direction mounting supported) |
| Reference: Dimensions | 42.0×67.0-73.0×78.0-85.3mm (varies depending on AC pin type) |
| Others | LPS compliant, RoHS 2 compliant |
Semi-Custom Support
For specification confirmation, quotations, or sample requests, please feel free to contact us. Examples of semi-custom support can be found on the Customization Case Studies page.