AC/DC Power Adapter Peak Current Issue Quickly Resolved with a Semi-Custom Solution
The power repeatedly shuts off during startup, and the cause is unknown.... What was happening with the commercially available third-party AC/DC Power Adapter used by the customer? This article briefly summarizes a real-world case in which we resolved a customer's issue, outlining the challenges from both procurement and technical perspectives and the approach taken to reach a solution. It offers valuable insights for companies considering measures to address peak current. We hope you will take a moment to read it.
目次

Case Study: Resolving Power Supply Issues Caused by Online-Sourced Products
This case study describes how we used our semi-custom power supply to resolve issues involving heat generation, shutdowns, and non-compliance with standards caused by a general-purpose AC/DC Power Adapter from another manufacturer that the customer purchased online, making replacement within a short period unavoidable.
- "The AC adapter shuts down due to peak current at startup."
- "We do not know how to properly match the Products with the AC/DC Power Adapter."
In addition to **the information required for adoption decisions (cost/lead time/standards compliance/mass-production risks)**, we will briefly explain the replacement procedure and key compatibility evaluation points.
Customer Challenges and Background
In the customer's production lot, startup inrush current caused the existing AC/DC Power Adapter (a 6 VDC, 2.8 A product from another manufacturer) to repeatedly experience sudden voltage drops and recovery. In addition, fluctuations in the OCP threshold were suspected due to changes in the internal layout of the other manufacturer's adapter. The customer contacted us to resolve these issues.
- Target equipment: Equipped with a motor (generates an instantaneous peak current at startup)
- Symptoms: The voltage repeatedly drops and recovers when the switch is turned on (became apparent in the latest lot)
- Procurement concern: The internal layout of the other manufacturer's adapter purchased online had been changed multiple times, potentially causing fluctuations in the OCP (overcurrent protection) threshold
Our Solution
Key Considerations
| Item | Current Situation | Considerations/Assumptions |
|---|---|---|
| Peak Current | 4.2 A instantaneous (measured value) | Compatibility with the OCP threshold must be verified |
| OCP Setting | Other manufacturer's product: Estimated 2.8 A | Prevent malfunctions by setting an adequate safety margin |
Process
- Customer Requirements Interview
Confirmed the failure symptoms, timing of occurrence, and operating environment
- Root Cause Analysis and Equipment Measurement
Measured current waveforms and estimated the overload protection operating point
- Design Review and Prototyping
Determined the optimal settings for the UV324 series and developed semi-custom specifications
- Evaluation and Verification
Conducted operational verification, safety testing, and long-term operation testing
- Mass-Production Implementation
Updated the BOM, finalized manufacturing procedures, and established a quality control system
- Customer Report
Explained the results, benefits, and future supply framework
[Key Point] Optimized overcurrent protection and leveraged an existing series to create a power supply capable of withstanding instantaneous peak currents
Based on the interview findings, we identified the cause by determining that the power supply was shutting down because the overcurrent protection function was being activated. Using our UV324 series, we developed a semi-custom specification in which overload protection does not activate at up to 4.2 A MAX. This allowed us to propose an improvement that achieved both cost efficiency and rapid development.
Results After Implementation
- The failure symptoms were eliminated, and the equipment no longer experienced repeated power drops or restarts
- Identifying the cause provided confidence from both procurement and technical perspectives
- Optimizing overload protection enabled stable operation even during peak current events
- The semi-custom solution was successfully implemented in mass production within a short period
- A policy for continued adoption was established, creating a stable supply framework
Customer Feedback
"The failure symptoms have been eliminated, and we are greatly reassured that the cause was properly identified. We intend to continue using UNIFIVE's Products."
- Development Representative at a Septic Tank and Wastewater Treatment Equipment Manufacturer
For Those Facing Similar Issues
When matching a Products with an adapter, Products that use motors, equipment incorporating such Products, or devices that use amplifiers may momentarily draw current exceeding their rated value. This can cause equipment malfunctions.
If you plan to use an adapter with this type of equipment, please contact us. We can provide advice and propose the optimal custom or semi-custom solution.