Noise Countermeasure Case Study for AC/DC Power Adapter for Communication Equipment | Verifying Cost Reduction Proposals Through Joint Measurements and Comparing Component Combinations
This case study describes how a cost reduction proposal for an AC/DC Power Adapter for communication equipment was verified through joint measurements at the customer's testing facility. Because the conducted noise margin did not meet the required standard, we replaced and compared the Transformer, MOSFET, and line filter one at a time. Without fundamentally changing the circuit, we addressed the issue by selecting appropriate components and adjusting the PCB layout.
This page presents a case study based on an inquiry from a communications equipment manufacturer regarding cost reduction and noise suppression for an AC/DC Power Adapter used in communications equipment. We conducted joint measurements at the customer's testing facility to verify whether the cost reduction proposal met the noise and Lightning Surge requirements. For conducted noise that did not meet the required standard, we replaced and compared components one by one to narrow down the appropriate countermeasures.
Case Overview: Cost Reduction and Noise Mitigation for an AC/DC Power Adapter for Communications Equipment
Together with the customer, we evaluated a cost-reduction proposal for the custom power supply used in the customer's communications equipment. We then implemented noise mitigation measures without fundamentally changing the circuit.
| Item | Details |
|---|---|
| Application | Communications equipment |
| Customization Type | Semi-custom (customer-specific specification revisions based on a standard product) |
| Base Model | 30 W AC/DC Power Adapter with Lightning Surge Protection, UZA130 Series (Inlet Type) |
| Customer Request | Cost reduction for the currently used AC/DC Power Adapter |
| Our Proposed Revisions | Case modification, downsizing of the Transformer, reduction in the number of components, and adoption of surface-mount components |
| Evaluation Method | Joint measurements using the customer's test equipment (Lightning Surge, conducted emissions, and radiated emissions) |
| Challenge | The conducted emissions margin (the margin relative to the limit) did not meet the customer's criteria |
| Components Compared | Transformer, MOSFET, and line filter |
| Circuit Changes | No fundamental changes (the PCB layout was adjusted to accommodate the change in the Transformer) |
| Next Step | The customer reevaluated a sample incorporating the mitigation measures |
Background: Reducing Costs by Reviewing the Currently Used AC/DC Power Adapter
The customer was considering ways to reduce the cost of our custom power supply used in its communications equipment.
We proposed reviewing the components and design. The main proposed changes included modifying the enclosure, downsizing the Transformer, reducing the number of components, and replacing components with chip components.
However, changing the components or design may affect resistance to noise and Lightning Surge. For communications equipment, it is essential to evaluate noise and Lightning Surge with the power supply connected to the equipment. Therefore, we and the customer decided to evaluate samples incorporating the proposed changes in combination with the customer's equipment.
Why Evaluation in Combination With the Equipment Is Necessary Even if the AC/DC Power Adapter Alone Meets the Standards
Even if the AC/DC Power Adapter alone meets EMI (electromagnetic interference) requirements, it may fail to meet noise standards when connected to the equipment (How to Select an AC/DC Power Adapter). Therefore, verification in combination with the equipment is essential (Causes of Buzzing or Humming Sounds From an AC/DC Power Adapter).
We also provide solutions for noise that occurs when our products are used in combination with end equipment. Our approach to countermeasures, including adjustments involving the customer's equipment, is explained in What Should I Do About Interference Caused by Radio-Frequency Noise?
Base Model: 30W Lightning Surge-Compatible AC/DC Power Adapter UZA130 Series
The base model is our 30W AC/DC Power Adapter UZA130 Series, designed with an emphasis on Lightning Surge protection. The Main Specifications are as follows. These specifications apply to the current standard products. Specifications for customers are adjusted based on these standard products.

| Item | UZA130 Series |
|---|---|
| Output | 12.0V/2.1A, 12.0V/2.5A |
| Input | AC100-120V (allowable range: AC90-132V), 50/60Hz (allowable range: 47-63Hz) |
| Voltage Accuracy | ±5% |
| Ripple/Noise | 200mV/300mV (2.1A), 300mV/300mV (2.5A) |
| Full-Load Efficiency | 82.53% (2.1A), 83.63% (2.5A) |
| Operating Temperature | 0-40°C |
| AC Input Type | Inlet (IEC 320 C8) |
| Dimensions | 113.5 x 54.0 x 36.3mm |
| Lightning Surge | High-voltage-resistant design compliant with IEC61000-4-5 requirements |
| Emissions | FCC Part 15-B/VCCI-B |
| Protection Circuits | Short-circuit protection/Overvoltage protection/Overcurrent protection/Overtemperature protection (optional) |
| Safety Standards | Please contact our sales department regarding the safety standards applicable to each model. |
"Ripple" and "noise" in the table indicate the magnitude of fluctuations contained in the output voltage (About Ripple and Noise). These are different from the conducted noise that presented an issue in this case.
We provide adjustments as custom power supplies to address requirements not covered by standard product specifications and to meet customers' cost targets. Other models with the same power rating are available in the 30W Series.
Issue Identified During Joint Measurement: Conducted Noise Margin Falls Short of the Standard
Our technical staff accompanied the customer to their testing facility and measured Lightning Surge, conducted noise, and radiated noise together with the customer. Since the customer and our company performed the measurements at the same location, this page refers to the process as "joint measurement."
Conducted noise is noise that travels through power lines. It is measured as disturbance voltage at the terminals. Radiated noise is noise emitted into the surrounding space. It is measured as disturbance field strength. Our reliability testing also includes disturbance voltage testing at the terminals (About Reliability Testing).
The customer had established its own standard for the required margin relative to the limit. Multiple samples had to meet this standard.
The joint measurement found no issues in the Lightning Surge test. However, the conducted noise margin fell short of the customer's standard. The radiated noise margin was also limited, so additional units were to be tested for verification.
Noise Countermeasure Process: Comparing the Effects of Replacing the Transformer, MOSFET, and Line Filter One at a Time
Using countermeasure components prepared in advance, we replaced the components one at a time and compared the conducted noise margins.
Before the joint testing, our development and manufacturing sites had prepared proposed countermeasures and components in case the product failed to meet the standards. For conducted noise, radiated noise, and Lightning Surge, we had even determined the order in which the countermeasures would be tested.
| Order | Replaced Component | Details | Conducted Noise Margin |
|---|---|---|---|
| 1 | Transformer | Revert to the Transformer used before the revision | Improved |
| 2 | MOSFET | Replace with a different model | Improved further |
| 3 | Line filter | Replace with one offering better characteristics | Improved further and exceeded the standard |
The comparison showed that the conducted noise margin improved with all three components: the Transformer, MOSFET, and line filter. Because we replaced the components one at a time, we were able to verify the effect of each component.
Based on the results of this comparison, we selected the countermeasures to implement.
Returning the Transformer to its pre-review specifications without fundamentally changing the circuit
We reverted the Transformer, which affected the margin, to its pre-review specifications. Because the terminal spacing (pitch) of the original Transformer did not match, we adjusted the PCB layout. There was no need to fundamentally change the circuit.
We do not adopt every cost-reduction proposal across the board. We determine whether to adopt each component based on the results of evaluations conducted in combination with the equipment. Modifications based on standard products require fewer new design processes, reducing development time and costs (What does power supply customization involve?).
When changing components, it is also necessary to assess the impact on safety standard certifications. Depending on the nature of the changes, certification of the differences may be required (Semi-customization workflow).
Key Points of This Case Study: Balancing Cost Reduction with Noise and Lightning Surge Requirements
We delivered samples incorporating the countermeasures to the customer and proceeded with reevaluations of Lightning Surge, conducted noise, and radiated noise. This case study highlights the following four key points.
- Verify cost-reduction proposals through evaluations conducted in combination with the customer's equipment.
- Prepare countermeasure components before testing in case the requirements are not met.
- Replace components one at a time to determine which ones improve the margin.
- Address the requirements through component selection and PCB layout without fundamentally changing the circuit.
Our in-house laboratory is equipped to test conducted emissions, electrostatic discharge (ESD), electrical fast transients (EFT), surges, EMI, and more (About Reliability Testing). As in this case study, our technical personnel also have experience accompanying customers during joint testing at their test facilities.
Customer Testimonials
![]() | "Even when proposing cost reductions, UNIFIVE verified noise and Lightning Surge performance according to our evaluation standards. During testing, their engineers replaced components on the spot and immediately showed us the next solution. They are a power supply manufacturer we can consult with confidence." - Design Engineer, Telecommunications Equipment Manufacturer |
Information to Prepare When Consulting Us About AC/DC Power Adapter Cost Reduction or Noise Countermeasures
When consulting us about noise that occurs when the adapter is used with your equipment, please provide the evaluation conditions and target margin. Based on the information provided, we will determine specific countermeasures and the evaluations required.
| Information | Examples |
|---|---|
| Equipment Used | Equipment or devices to be evaluated in combination with the AC/DC Power Adapter |
| Load Conditions | Current and input voltage during measurement |
| Evaluation Method and Standards | Standard names, classifications, and limits for conducted and radiated noise |
| Target Margin | Desired margin below the limit and the number of samples used for assessment |
| Lightning Surge Test Conditions | Standard name, applied voltage, and application points |
| Cost Reduction Requirements | Parts that may be revised and parts that must not be changed |
| Power Supply Currently Used | Model number and specifications |
You may consult us even if you do not have all the information ready. Our sales team will guide you through the process while confirming the necessary information.
Frequently Asked Questions About Noise Suppression for AC/DC Power Adapter for Communications Equipment
If components are changed to reduce costs, will noise and Lightning Surge resistance be affected?
It may be affected. Therefore, we test samples of proposed revisions in combination with the customer's equipment. In this case, we restored the Transformer, which affected the conducted noise margin, to its original specifications and replaced other components for comparison.
Is it necessary to redesign the circuit to suppress noise from the AC/DC Power Adapter?
Not necessarily. In this case, we addressed the issue by selecting components and adjusting the PCB layout without fundamentally changing the circuit. We have also addressed noise caused by wiring conditions on the cable side (Semi-Custom AC/DC Power Adapter Case Study for Industrial Equipment).
Can the AC/DC Power Adapter manufacturer attend the noise evaluation?
Please contact us to discuss your requirements. In this case, one of our engineers attended a joint measurement session at the customer's test facility. By replacing and comparing components on-site, we were able to quickly narrow down the appropriate countermeasures. If you inform us of the evaluation conditions in advance, we can prepare countermeasure components for the measurements.
Do You Have Any of These Concerns?
- You want to reduce the cost of your current AC/DC Power Adapter, but are concerned about having to reevaluate noise and Lightning Surge performance
- When combined with your equipment, the noise margin does not meet the target
- You want to identify which components are affecting noise performance
- You want to implement noise countermeasures without redesigning the circuit
- You are unsure whether a standard product is sufficient or a custom solution is required
We provide cost reduction and noise countermeasures for AC/DC Power Adapter used in communication equipment, information technology equipment, IoT devices, and more. Our custom power supplies range from semi-custom solutions based on standard products to fully custom solutions designed from the circuit level. We assess feasibility and the required testing on a case-by-case basis, so please tell us about your requirements.
Inquire About Cost Reduction and Noise Countermeasures
Related Case Studies and Pages
- Semi-Custom AC/DC Power Adapter Case Study for Industrial Equipment (Noise Reduction and Cable Specification Changes)
- Fully Custom AC/DC Power Adapter Case Study for Information Technology Equipment (Communications Equipment and Gateway Applications)
- Fully Custom Lightning Surge Protection Case Study for Outdoor Communications Equipment
- Lightning Surge, Noise, and Harmonic Countermeasures
- Noise Suppression for Low-Noise Applications
- AC/DC Power Adapters for Information and Communications Equipment
- Download the Comprehensive product catalog
*This case study is published within the scope of the customer's authorization. Company names, quantities, prices, and other details are not disclosed.