Evaluating Light-Load Noise in Combination with Equipment | Semi-Custom Case Study of an AC/DC Power Adapter for Monitoring Equipment
This is a case study of noise and Lightning Surge countermeasures for an AC/DC Power Adapter designed for monitoring equipment. Testing in combination with the equipment revealed an issue with the conducted noise voltage under light-load conditions. We proposed a semi-custom solution that utilized the existing circuit board, including the addition of a Varistor and a change to the Y capacitor.
This page presents noise suppression and Lightning Surge protection for AC/DC Power Adapter used with surveillance equipment, based on an inquiry from a surveillance equipment manufacturer. We considered the power supply and equipment as an integrated system when exploring possible countermeasures. This semi-custom case study involved refining the specifications for sample modification and reevaluation.
Case Study Overview: Noise and Lightning Surge Countermeasures for an AC/DC Power Adapter Used with Monitoring Equipment
Based on a standard wide-temperature-range AC/DC Power Adapter, we proposed noise and Lightning Surge countermeasures that did not require redesigning the PCB.
| Item | Details |
|---|---|
| Application | Monitoring equipment |
| Customization Type | Semi-custom (component changes based on a standard product) |
| Base Model | SNI360-2425 (24 V output, 45 W, wide-temperature-range, inlet type) |
| Challenges | During testing in combination with the customer's equipment, conducted terminal noise voltage under a load of approximately 5 W became an issue. Compliance with the specified Lightning Surge conditions was also required. |
| Our Proposed Countermeasures | Adding a Varistor, changing the capacitance of the Y capacitor, and changing the mounting positions of the diode and jumper |
| PCB Changes | Not required (the Varistor uses an existing mounting position on the PCB) |
| Other Requirements | Use a straight-type DC plug |
| Process | Confirm the issue through the customer's testing, modify the sample used for testing, and perform another evaluation |
| Customer Feedback | The customer was very satisfied with our solution |
Consultation Details: Noise Terminal Voltage Under Light-Load Conditions Became an Issue During Evaluation with the Equipment
During testing that combined the customer's equipment with our AC/DC Power Adapter, noise terminal voltage became an issue under a load condition of approximately 5 W.
Noise terminal voltage is an EMC (electromagnetic compatibility) test parameter that measures the level of noise transmitted through power lines (conducted noise). We also include noise terminal voltage testing in our reliability testing program (About Reliability Testing).
The customer approached us with two requests. The first was to meet EMI (electromagnetic interference) requirements under this load condition. The second was to meet the Lightning Surge requirements. Additional verification was required to determine whether the standard product sample could meet both requirements without modification.
Why Noise Issues Can Arise When an AC/DC Power Adapter Is Combined with a Device, Even If the Adapter Alone Meets the Standards
Even if an AC/DC Power Adapter alone meets EMI requirements, it may fail to meet noise standards when connected to a device (How to Select an AC/DC Power Adapter). Therefore, testing the adapter in combination with the target device is essential (Causes of Humming or Buzzing Sounds from an AC/DC Power Adapter).
Switching power supplies control their switching frequency and pulse width according to the load level (What Is a Switching Power Supply?). In this case, the issue was found under a load lighter than the rated load.
We also provide solutions for noise that occurs when our products are combined with end-use equipment. Our approach to countermeasures, including adjustments made in conjunction with customers' equipment, is explained in How Can Problems Caused by Radio-Frequency Noise Be Resolved?
Base Model: Wide-Temperature-Range 45W AC/DC Power Adapter SNI360-2425
We used the 24V output model (SNI360-2425) of our standard wide-temperature-range SNI360, which can be used from -20 to +60 deg C, as the base model. The Main Specifications are shown below. These are the specifications of the current standard product.

| Item | SNI360-2425 |
|---|---|
| Output | 24.0V / 1.9A (45W when used from -20 to +60 deg C) 24.0V / 2.5A (60W when used from 0 to 40 deg C) |
| Input | AC100-240V (allowable range: AC90-264V), 50/60Hz (allowable range: 47-63Hz) |
| Voltage Accuracy | +/-5% |
| Ripple / Noise | 240mV / 480mV |
| Average Efficiency | 87.74% (1.9A), 88.00% (2.5A) |
| No-Load Power Consumption | 0.21W |
| AC Input Type | Inlet (IEC 320 C8) |
| Dimensions | 36.3 x 54.0 x 113.5mm |
| Protection Circuits | Short-Circuit Protection / Overvoltage Protection / Overcurrent Protection |
| Emissions | FCC Part15 Class B / EN(CISPR)55032 Class B / VCCI Class B / CNS13438 / BS EN 55032 |
| Immunity | EN55035 / BS EN 55035 (including EN61000-4-2 / -4-3 / -4-4 / -4-5 / -4-6 / -4-8 / -4-11) |
| Safety Standards | Safety certification has been obtained for models used from 0 to 40 deg C. Please contact our sales department for the standards applicable to each model. |
"Ripple" and "noise" in the table indicate the magnitude of fluctuations contained in the output voltage (About Ripple and Noise). These are different from conducted emission voltage.
As a standalone unit, the current standard product complies with the emissions and immunity standards shown in the table above. However, evaluation in combination with equipment is required for each customer's device. We adjust any aspects not covered by the standard product specifications as a custom power supply.
Other voltages in the same series are available in the Wide-Temperature-Range 45W Series. The features of wide-temperature-range Product Features can be found on the AC/DC Power Adapters for Wide Temperature Ranges page.
Our Proposed Noise and Lightning Surge Countermeasures: Component Changes Using the Existing PCB
The engineers at our development and manufacturing facility proposed adding components, changing component values, and reviewing component placement without redesigning the PCB.
| Item to Be Changed | Proposed Change |
|---|---|
| Varistor | Add one using an existing mounting location on the PCB. |
| Y Capacitor | Change the capacitance. |
| Diode and Jumper | Change their mounting locations. |
| DC Plug | Use a straight type (at the customer's request). |
According to our engineers, the Varistor can use an existing mounting location on the PCB, so no PCB modification is required.
Varistor are generally used to protect against Lightning Surge. As a Lightning Surge countermeasure, we often propose adding a Varistor or Surge Arrester to the PCB of an AC/DC Power Adapter (Lightning Surge, Noise, and Harmonic Countermeasures). Reviewing capacitors, such as Y capacitors, is a method commonly used to reduce noise (Semi-Custom AC/DC Power Adapter Case Study for Industrial Equipment).
DC plugs are available in straight and L-shaped types (What Is a DC Plug?). We also change the shape of the DC plug to suit the customer's equipment.
Advantages of Semi-Customization Without Redesigning the PCB
Semi-customization modifies certain specifications based on our standard products. It does not require the development of new circuits, Transformer, or enclosures (What Is Power Supply Customization?).
When changing components, the impact on safety certifications must also be assessed. Semi-customization allows us to leverage certifications obtained for the base model. Depending on the modifications, the product may be shipped without recertification, or certification of the differences may be required (Semi-Customization Workflow).
Depending on the model, our Products designed for a wide temperature range can be equipped with surge protection components such as Varistor (AC/DC Power Adapters for Wide Temperature Ranges). If greater surge resistance is required, we can design a fully customized power supply (Fully Customized Lightning Surge Protection for Outdoor Communication Equipment).
Process: From Customer Evaluation to Modification and Reevaluation of Returned Samples
We reviewed the conditions under which the issues were identified during the customer's evaluation. We then discussed having the customer return the samples used for the evaluation so that we could modify and reevaluate them.
| Step | Description | Responsible Party |
|---|---|---|
| 1 | Provide a sample of the standard product | Our company |
| 2 | Evaluate the sample in combination with the customer's equipment | Customer |
| 3 | Identify an issue with conducted emission voltage under light-load conditions | Customer |
| 4 | Confirm the evaluation conditions and additional requirement (Lightning Surge) | Customer and our company |
| 5 | Propose adding components, changing component values, and changing mounting positions | Our company |
| 6 | Have the customer return the sample used for evaluation, then modify and reevaluate it (subject to consultation) | Customer and our company |
For semi-custom products, the customer evaluates a prototype in combination with the actual equipment. Based on the evaluation results, we produce another prototype or make partial modifications. We then finalize the specifications based on the reevaluation results and proceed with certification updates and mass production (Semi-Customization Workflow).
Our in-house laboratory is equipped to test conducted emissions, electrostatic discharge (ESD), electrical fast transients (EFT), surges, EMI, and more. We can also conduct tests under conditions tailored to customer requirements (About Reliability Testing).
Customer Testimonials
The customer was very satisfied with our service.
![]() | "Communication with the experienced team at UNIFIVE went smoothly. We were able to handle the matter while receiving precise advice." - Representative of a monitoring equipment manufacturer |
Information to Prepare When Consulting Us About Noise and Lightning Surge Countermeasures for AC/DC Power Adapter
When consulting us about noise or Lightning Surge that occur when the adapter is used with your equipment, please provide the measurement conditions, waveforms, and operating environment. Based on the information provided, we will consider specific countermeasures and the evaluations required.
| Information | Examples |
|---|---|
| Applicable standards | Standard name and classification (e.g., VCCI Class B), limit values |
| Measurement conditions | Load conditions, input voltage, wiring method |
| Measurement results | Waveforms or spectra, frequency ranges exceeding the limits |
| Lightning Surge test conditions | Standard name, applied voltage, application points |
| Equipment grounding conditions | Whether the secondary side is grounded and how it is connected. The path through which a Lightning Surge enters varies depending on the grounding conditions. |
| Operating environment | Installation location, ambient temperature |
| Power supply currently in use | Model number, specifications |
You may consult us even if you do not have all the information available. Our sales representative will assist you while confirming the necessary information.
Frequently Asked Questions About Noise and Lightning Surge Protection for AC/DC Power Adapter
Can Lightning Surge protection be added to a standard AC/DC Power Adapter afterward?
Yes. Depending on the model, we can add surge protection components, such as Varistor, to the circuit board of a standard product. In this case, we proposed adding a Varistor to an existing mounting location on the circuit board. The components that can be added vary by model. If greater surge resistance is required, we can design a fully customized power supply (Lightning Surge, Noise, and Harmonic Countermeasures).
Can noise countermeasures be implemented for an AC/DC Power Adapter without redesigning the circuit board?
Yes. We first consider methods such as changing the values of components like Y capacitors, adding components, or changing their mounting locations. The solution proposed in this case does not require any changes to the circuit board (PCB). We have also addressed noise caused by wiring conditions by implementing countermeasures on the cable side (Case Study: Semi-Custom AC/DC Power Adapter for Industrial Equipment).
Is it too late to consult you after an issue is identified during evaluation with the equipment?
No. We also accept consultations after an issue has been identified during a customer's evaluation. For semi-custom products, we respond based on the evaluation results by creating another prototype or making partial modifications (Semi-Customization Workflow). Providing the evaluation conditions and measurement results will help us proceed with our review more quickly.
Do You Have Any of These Concerns?
- Noise occurs only when the adapter is connected to the equipment
- The product fails noise testing under specific load conditions
- The required Lightning Surge tolerance exceeds the specifications of standard products
- Noise and surge countermeasures are needed without redesigning the circuit board
- It is difficult to determine whether a standard product is sufficient or a custom solution is required
We provide noise and Lightning Surge countermeasures for AC/DC Power Adapter used with monitoring equipment, communication equipment, IoT devices, and other products. Our custom power supply solutions range from semi-custom designs based on standard products to fully custom designs developed at the circuit level. We will assess feasibility and the required testing based on your specific needs, so please let us know your requirements.
Contact Us About Noise and Surge Countermeasures
You can view our standard products in the Comprehensive product catalog.
*To protect the customer's identity, company names, Products names, quantities, prices, and other details have not been disclosed in this case study.